Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Clin Med ; 12(23)2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38068420

RESUMO

In current clinical practice, commissural alignment of the transcatheter heart valve (THV) during transcatheter aortic valve implantation (TAVI) is seldom achieved. Orientation of the THV within the aortic root and the subsequent influence upon leaflet haemodynamic function, coronary blood flow, and ease of access to the coronary ostia are gaining significant interest. Herein, we review the incidence and clinical implications of commissural misalignment in TAVI and offer thorough descriptions of how optimal alignment can be achieved with several different contemporary THV devices.

2.
J Clin Med ; 12(24)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38137816

RESUMO

This review article describes in depth the current usefulness of transesophageal echocardiography in patients who undergo transcatheter aortic valve replacement. Pre-intervention, 3D-transesophageal echocardiography allows us to accurately evaluate the aortic valve morphology and to measure the valve annulus, helping us to choose the appropriate size of the prosthesis, especially useful in cases where the computed tomography is not of adequate quality. Although it is not currently used routinely during the intervention, it remains essential in those cases of greater complexity, such as for patients with greater calcification and bicuspid valve, mechanical mitral prosthesis, and "valve in valve" procedures. Three-dimensional transesophageal echocardiography is the best technique to detect and quantify paravalvular regurgitation, a fundamental aspect to decide whether immediate valve postdilation is needed. It also allows to detect early any immediate complications such as cardiac tamponade, aortic hematoma or dissection, migration of the prosthesis, malfunction of the prosthetic leaflets, or the appearance of segmental contractility disorders due to compromise of the coronary arteries ostium. Transesophageal echocardiography is also very useful in follow-up, to check the proper functioning of the prosthesis and to rule out complications such as thrombosis of the leaflets, endocarditis, or prosthetic degeneration.

3.
J Clin Med ; 11(9)2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35566402

RESUMO

Background: There is no consensus on the best intraprocedural parameter to evaluate residual mitral regurgitation (MR) after transcatheter edge-to-edge mitral repair (TEER). Thus, our aim was to evaluate the predictive value of different MR parameters from intraprocedural transesophageal echocardiogram (TEE) for grading in consecutive transthoracic echocardiogram (TTE) during the follow up. Methods: All the consecutive patients who underwent TEER with MitraClip between 2010 and 2020 in our center were considered. TEE-derived immediate postprocedural MR parameters were reassessed to blindly compare them with follow up MR grading in sequential TTE. Results: We finally included 88 patients (64.8% males; 76 ± 10 years-old). Significant MR was detected in 14.3% of the cases at 6 months, in similar proportion than at postprocedural at 1 month. Among all the intraprocedural TEE quantitative parameters only additive and maximum VC were associated with significant MR persistence. Moreover, on ROC analysis maximum VC demonstrated an excellent discriminatory power (AUC 0.96; p < 0.001) to identify MR ≥ III at 6 months. Thus, a cut-off point of 0.45 cm demonstrated 88% sensitivity and 89% specificity. Conclusion: Among intraprocedural TEE parameters to evaluate residual MR in TEER, maximum and additive VC were the most reliable to predict persistence of significant insufficiency.

4.
Catheter Cardiovasc Interv ; 98(4): E617-E625, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33856097

RESUMO

BACKGROUND: Very few data exist on percutaneous mitral valve repair (PMVr) in unstable patients with concomitant moderate-severe mitral regurgitation (MR). The purpose of this systematic review was to evaluate baseline characteristics, management and clinical outcomes of critically ill patients undergoing PMVr with MitraClip. METHODS: We conducted a systematic review of the published data on MitraClip from its first use in 2003 to December 2020. Studies referring to critically ill patients in cardiogenic shock or acute refractory pulmonary edema were included. A total of 40 publications including 254 patients with significant MR (Grade 4 in 91%) were included. RESULTS: Mean age was 70 ± 12 years with mean Euroscore II and STS of 21 ± 13 and 20.5 ± 16, respectively. Clinical presentation was with cardiogenic shock and acute myocardial infarction in 72.8 and 60.0% of patients, respectively. Device success was achieved in 238 (93.7%) patients with a significant reduction in MR (Grade ≤ 2 in 91.8%, p < .001). The median weaning time from the procedure, to discontinuation of mechanical circulatory or respiratory support, was 2 days (IQR 1-4), with an in-hospital mortality and non-fatal complication rate of 12.6 and 9.1%, respectively. Kaplan-Meier curves estimated an overall mortality rate of 39.1% at 12-month follow-up, with persistent reduction in MR severity for survivors (Grade ≤ 2 in 81.3%) and one case of mitral valve reintervention. CONCLUSIONS: Percutaneous mitral valve repair with MitraClip device is a technically feasible and potentially viable management option in high-risk patients with cardiogenic shock or refractory pulmonary edema and concomitant moderate-severe MR. Prospective trials are required to confirm these findings, and definitively determine the value of MitraClip in hemodynamically unstable patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
5.
Rev. esp. cardiol. (Ed. impr.) ; 74(2): 159-166, Feb. 2021. tab, graf, ilus
Artigo em Inglês, Espanhol | IBECS | ID: ibc-230833

RESUMO

Introducción y objetivos El análisis de la deformación miocárdica puede aportar información adicional a la fracción de eyección del ventrículo izquierdo (FEVI) en la miocardiopatía dilatada no isquémica (MDNI). El objetivo es analizar la factibilidad del estudio del strain del ventrículo izquierdo mediante feature tracking (FT) de cardiorresonancia magnética en la MDNI y determinar su relevancia clínica y pronóstica. Métodos Se incluyó retrospectivamente a los pacientes consecutivos con MDNI sometidos a cardiorresonancia magnética. Se obtuvieron el strain global longitudinal, circunferencial y radial del ventrículo izquierdo de secuencias convencionales de cine mediante un software de análisis de FT. Se evaluó su asociación con el evento combinado (insuficiencia cardiaca, implante de desfibrilador en prevención secundaria y muerte). Resultados Se pudo realizar el FT en los 98 pacientes evaluados (edad, 68± 13 años; el 72% varones). La concordancia intraobservador e interobservadores fue buena para el strain global longitudinal y circunferencial, y más limitada para el radial. El strain global circunferencial se asoció de manera independiente (OR=1,16; p=0,045) con la normalización de la FEVI en el seguimiento y fue el único parámetro morfológico con asociación independiente (OR=1,15; p=0,038) con el evento combinado. Un valor <–8,2% fue capaz de predecir la aparición de este evento en el seguimiento (Log-ranktest, 4,6; p=0,032) Conclusiones El análisis del strain del ventrículo izquierdo mediante FT es factible y reproducible en MDNI. El strain global circunferencial fue capaz de predecir la recuperación de la FEVI y la aparición de eventos cardiovasculares mayores en el seguimiento. (AU)


Introduction and objectives Myocardial strain analysis could provide additional information to left ventricular ejection fraction (LVEF) in nonischemic dilated cardiomyopathy (NIDC). Our aim was to analyze the feasibility of left ventricular strain evaluation using cardiac magnetic resonance feature tracking (FT) in NIDC, and to determine its clinical and prognostic impact. Methods We retrospectively included consecutive patients with NIDC who underwent cardiac magnetic resonance. Left ventricular global longitudinal, circumferential and radial strain were obtained from standard cine sequences using FT analysis software. We evaluated their association with a composite endpoint (heart failure, implantable cardioverter-defibrillator in secondary prevention, or death). Results FT analysis could be performed in all of the 98 patients (mean age 68±13 years, 72% men). Intra- and interobserver concordance was good for global longitudinal and circumferential strain but was worse for radial strain. Global circumferential strain was independently associated (OR, 1.16; P=.045) with LVEF normalization during follow-up and was the only morphological parameter independently associated with the composite endpoint (OR, 1.15; P=.038). A cutoff value <−8.2% was able to predict the incidence of this event during follow-up (log-rank 4.6; P=.032). Conclusions Left ventricular strain analysis with FT is feasible and reproducible in NIDC. Global circumferential strain was able to predict LVEF recovery and the appearance of major cardiovascular events during follow-up. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/diagnóstico , Seguimentos , Estudos de Viabilidade , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia
6.
Cardiovasc Revasc Med ; 29: 18-21, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33008787

RESUMO

INTRODUCTION: An ancillary advantage of bioresorbable scaffolds is the possibility of non-invasive imaging assessment of the treated coronary segment. Cardiac computed tomography angiography (CCTA) studies of resorbable magnesium scaffolds (RMS) are scarce. METHODS: In this collaborative, international study, nine patients who had an RMS implanted underwent CCTA as part of follow-up assessment. Core-lab blinded quantitative and qualitative assessment was performed by an independent CCTA investigator. RESULTS: Eight studies were amenable for quantitative analysis, and the blinded CT investigator successfully located and evaluated patency of RMS in all cases. The CCTA follow-up in-scaffold percentage diameter stenosis and area stenosis was 22.2% (12.4-30) and 39.1% (0.23-0.50), in keeping with mild in-scaffold late loss and underlying plaque growth. Moreover, a detailed coronary plaque characterization at treated segments was feasible (fibrous plaque in 69.9%, fibrofatty in 17.13%, necrotic in 4.78% and calcium in 5.72%). As in 6 out of 8 cases, the presentation was an acute coronary syndrome, these preliminary results could suggest plaque stabilization and a good coronary vessel healing with RMS. CONCLUSION: Non-invasive, follow-up assessment of RMS with CCTA is feasible. Further CCTA studies for either clinical or research purposes with the present and upcoming generation of resorbable magnesium scaffolds are warranted.


Assuntos
Doença da Artéria Coronariana , Magnésio , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Seguimentos , Humanos , Tomografia Computadorizada por Raios X
7.
Rev Esp Cardiol (Engl Ed) ; 74(2): 159-166, 2021 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32198007

RESUMO

INTRODUCTION AND OBJECTIVES: Myocardial strain analysis could provide additional information to left ventricular ejection fraction (LVEF) in nonischemic dilated cardiomyopathy (NIDC). Our aim was to analyze the feasibility of left ventricular strain evaluation using cardiac magnetic resonance feature tracking (FT) in NIDC, and to determine its clinical and prognostic impact. METHODS: We retrospectively included consecutive patients with NIDC who underwent cardiac magnetic resonance. Left ventricular global longitudinal, circumferential and radial strain were obtained from standard cine sequences using FT analysis software. We evaluated their association with a composite endpoint (heart failure, implantable cardioverter-defibrillator in secondary prevention, or death). RESULTS: FT analysis could be performed in all of the 98 patients (mean age 68±13 years, 72% men). Intra- and interobserver concordance was good for global longitudinal and circumferential strain but was worse for radial strain. Global circumferential strain was independently associated (OR, 1.16; P=.045) with LVEF normalization during follow-up and was the only morphological parameter independently associated with the composite endpoint (OR, 1.15; P=.038). A cutoff value <-8.2% was able to predict the incidence of this event during follow-up (log-rank 4.6; P=.032). CONCLUSIONS: Left ventricular strain analysis with FT is feasible and reproducible in NIDC. Global circumferential strain was able to predict LVEF recovery and the appearance of major cardiovascular events during follow-up.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Estudos de Viabilidade , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos
9.
Coron Artery Dis ; 31(3): 293-299, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31658141

RESUMO

BACKGROUND: Spontaneous coronary artery dissection (SCAD) is an infrequent cause of acute coronary syndrome (ACS); however, its detection carries relevant clinical implications. Cardiac computed tomography (CCT) has been found to be useful for follow-up, but data during the acute phase are scarce. Thus, our aim was to evaluate the early diagnostic ability of CCT to detect SCAD. METHODS: We retrospectively analyzed all the in-hospital CCT performed in a prospective cohort of patients with SCAD from 2012 to 2016. An independent expert blindly evaluated the studies and described the radiologic characteristics of the lesions. These features were compared with the invasive coronary angiography (ICA) and optical coherence tomography (OCT) findings. RESULTS: 18 lesions were analyzed from 12 episodes identified in 11 patients (100% females; median age of 57 years old). CCT recognized the presence of SCAD in 14 (78%) of the lesions, with four different morphological patterns. Most commonly (10, 71%) SCAD presented as a diffuse lumen narrowing surrounded by a 'sleeve-like' wall thickening, which corresponded to intramural hematoma in OCT evaluation. When compared with ICA, CCT showed a positive correlation (Spearman's Rho = 0.775; P = 0.001) and excellent concordance (ICC = 0.8; P = 0.004) in stenosis grading, but not for lesion length and minimal luminal area. CONCLUSION: CCT was able to identify the presence of SCAD in most of the patients in the acute phase of this elusive and challenging clinical entity. In addition, in this setting, CCT revealed unique and distinct radiologic features and provided a precise assessment of lesion severity.


Assuntos
Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Tomografia de Coerência Óptica , Tomografia Computadorizada por Raios X , Doenças Vasculares/congênito , Estudos de Coortes , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/fisiopatologia , Feminino , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/etiologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/fisiopatologia , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Doenças Vasculares/complicações , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/fisiopatologia
10.
JACC Case Rep ; 2(11): 1702-1707, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34317039

RESUMO

Some coronary artery anomalies are associated with increased risk of sudden cardiac death and myocardial infarction in young patients. There are few data on the clinical and prognostic relevance of isolated origin of the left circumflex artery from the pulmonary artery, an extraordinarily rare variant of anomalous left coronary artery from the pulmonary artery. (Level of Difficulty: Intermediate.).

13.
Rev. esp. cardiol. (Ed. impr.) ; 72(5): 392-397, mayo 2019. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-188386

RESUMO

Introducción y objetivos: Los tratamientos actuales de la estenosis aórtica (EAo) grave incluyen el implante percutáneo de válvula aórtica (TAVI) y la cirugía de sustitución valvular aórtica (SVAo). El objetivo es describir la evolución de los pacientes con EAo grave tras la indicación de intervención, las variables que influyen en su pronóstico y los determinantes de un tiempo de espera superior a 2 meses. Métodos: Subanálisis del registro IDEAS (Influencia del Diagnóstico de Estenosis Aórtica Severa) en los pacientes a los que se indicó intervención. Resultados: De 726 pacientes con EAo grave diagnosticada en enero de 2014, se indicó intervención a 300 que son el foco del presente estudio. La media de edad era 74,0 +/- 9,7 años. Se intervino a 258 pacientes (86,0%): 59 con TAVI y 199 con SVAo. Al año, 42 (14,0%) continuaban sin intervención, ya sea por seguir en espera (34) o haber fallecido (8). La mitad de los pacientes que murieron antes del procedimiento fallecieron en los primeros 100 días. El tiempo hasta la intervención fue 2,9 +/- 1,6 meses para el TAVI y 3,5 +/- 0,2 meses para la SVAo (p = 0,03). Los predictores de mortalidad independientes fueron el sexo masculino (HR = 2,6; IC95%, 1,1-6,0), la insuficiencia mitral moderada-grave (HR = 2,6; IC95%, 1,5-4,5), la movilidad reducida (HR = 4,6; IC95%, 1,7-12,6) y la falta de intervención (HR = 2,3; IC95%, 1,02-5,03). Conclusiones: Los pacientes con EAo grave en espera de intervención tienen alto riesgo de mortalidad. Hay indicadores clínicos asociados con peor pronóstico que podrían indicar la necesidad de una intervención precoz


Introduction and objectives: Current therapeutic options for severe aortic stenosis (AS) include transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). Our aim was to describe the prognosis of patients with severe AS after the decision to perform an intervention, to study the variables influencing their prognosis, and to describe the determinants of waiting time > 2 months. Methods: Subanalysis of the IDEAS (Influence of the Severe Aortic Stenosis Diagnosis) registry in patients indicated for TAVI or SAVR. Results: Of 726 patients with severe AS diagnosed in January 2014, the decision to perform an intervention was made in 300, who were included in the present study. The mean age was 74.0 +/- 9.7 years. A total of 258 (86.0%) underwent an intervention: 59 TAVI and 199 SAVR. At the end of the year, 42 patients (14.0%) with an indication for an intervention did not receive it, either because they remained on the waiting list (34 patients) or died while waiting for the procedure (8 patients). Of the patients who died while on the waiting list, half did so in the first 100 days. The mean waiting time was 2.9 +/- 1.6 for TAVI and 3.5 +/- 0.2 months for SAVR (P = .03). The independent predictors of mortality were male sex (HR, 2.6; 95%CI, 1.1-6.0), moderate-severe mitral regurgitation (HR, 2.6; 95%CI, 1.5-4.5), reduced mobility (HR, 4.6; 95%CI, 1.7-12.6), and non intervention (HR, 2.3; 95%CI, 1.02-5.03). Conclusions: Patients with severe aortic stenosis a waiting therapeutic procedures have a high mortality risk. Some clinical indicators predict a worse prognosis and suggest the need for early intervention


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Progressão da Doença , Listas de Espera , Indicadores de Morbimortalidade , Doença Catastrófica , Estudos Prospectivos , Índice de Gravidade de Doença
15.
Rev Esp Cardiol (Engl Ed) ; 72(5): 392-397, 2019 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29997054

RESUMO

INTRODUCTION AND OBJECTIVES: Current therapeutic options for severe aortic stenosis (AS) include transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). Our aim was to describe the prognosis of patients with severe AS after the decision to perform an intervention, to study the variables influencing their prognosis, and to describe the determinants of waiting time > 2 months. METHODS: Subanalysis of the IDEAS (Influence of the Severe Aortic Stenosis Diagnosis) registry in patients indicated for TAVI or SAVR. RESULTS: Of 726 patients with severe AS diagnosed in January 2014, the decision to perform an intervention was made in 300, who were included in the present study. The mean age was 74.0 ± 9.7 years. A total of 258 (86.0%) underwent an intervention: 59 TAVI and 199 SAVR. At the end of the year, 42 patients (14.0%) with an indication for an intervention did not receive it, either because they remained on the waiting list (34 patients) or died while waiting for the procedure (8 patients). Of the patients who died while on the waiting list, half did so in the first 100 days. The mean waiting time was 2.9 ± 1.6 for TAVI and 3.5 ± 0.2 months for SAVR (P = .03). The independent predictors of mortality were male sex (HR, 2.6; 95%CI, 1.1-6.0), moderate-severe mitral regurgitation (HR, 2.6; 95%CI, 1.5-4.5), reduced mobility (HR, 4.6; 95%CI, 1.7-12.6), and nonintervention (HR, 2.3; 95%CI, 1.02-5.03). CONCLUSIONS: Patients with severe aortic stenosis awaiting therapeutic procedures have a high mortality risk. Some clinical indicators predict a worse prognosis and suggest the need for early intervention.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Tomada de Decisão Clínica , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/mortalidade , Prognóstico , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores Sexuais , Espanha/epidemiologia , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/mortalidade , Listas de Espera
17.
Echocardiography ; 35(11): 1812-1817, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30079468

RESUMO

INTRODUCTION: Mitral regurgitation severity assessment is usually carried out using qualitative, semiquantitative, and quantitative parameters. The mitral valve navigation (MVN) tool allows to measure the mitral effective regurgitant orifice (MERO) from 3D echo datasets. Our aim was to validate the MVN as a new tool to quantify MERO. A secondary aim was to assess the intra- and interobserver variability. METHODS: This is a retrospective study in which consecutive subjects undergoing a transoesophageal echocardiogram for more than mild mitral regurgitation evaluation were included. MERO measurement obtained by means of 3D color Doppler was used as the gold standard method for comparison. In every patient, MERO was also obtained using the MVN tool. RESULTS: Fifty-nine consecutive patients were analyzed (47.5% female; mean age 50.8 years). Mitral regurgitation was moderate in 23 (39%) and severe in 36 (61%) patients. Forty patients (67.8%) had a primary and 19 (32.2%) a secondary mitral regurgitation. The intraclass correlation coefficient (ICC) between 3D color Doppler and MVN was excellent (ICC: 0.95; 95% CI: 0.82 to 0.98; P < 0.001) in the total group and for patients with primary and secondary mitral regurgitation. Intra- and interobserver agreements were also good. CONCLUSIONS: Mitral valve navigator shows an excellent accuracy for measuring MERO when the transoesophageal 3D color Doppler is used as the reference method, either primary or secondary mitral regurgitation. Intraobserver reproducibility and interobserver reproducibility are also excellent. These findings make this software a good alternative method to measure mitral regurgitation severity.


Assuntos
Ecocardiografia Tridimensional/instrumentação , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/instrumentação , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
18.
Rev. esp. cardiol. (Ed. impr.) ; 71(8): 643-655, ago. 2018. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-178618

RESUMO

En cardiología, es esencial disponer de tecnología adecuada, actualizada y en buenas condiciones de funcionamiento. En España, el marco económico ha impactado fuertemente en los programas de renovación de tecnología y la obsolescencia es un problema creciente. El actual informe trata de dar respuesta al momento y las condiciones que deben concurrir para plantear la actualización, el reemplazo o la adopción de nuevas tecnologías en el ámbito de la cardiología


Adequate, updated and functional technology is essential in cardiology. In Spain, the economic scenario has strongly impacted technology renewal programs and obsolescence is a growing problem. The current report attempts to describe the current situation and the conditions that must concur to update, replace or adopt new technologies in the field of cardiology


Assuntos
Humanos , Doenças Cardiovasculares/diagnóstico por imagem , Técnicas de Imagem Cardíaca/tendências , Desenvolvimento Tecnológico/métodos , Processamento de Imagem Assistida por Computador/tendências , Tecnologia Culturalmente Apropriada , Equipamentos para Diagnóstico/tendências
19.
Rev Esp Cardiol (Engl Ed) ; 71(8): 643-655, 2018 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29941313

RESUMO

Adequate, updated and functional technology is essential in cardiology. In Spain, the economic scenario has strongly impacted technology renewal programs and obsolescence is a growing problem. The current report attempts to describe the current situation and the conditions that must concur to update, replace or adopt new technologies in the field of cardiology.


Assuntos
Técnicas de Imagem Cardíaca/estatística & dados numéricos , Cardiologia , Diagnóstico por Imagem/estatística & dados numéricos , Arquitetura Hospitalar , Técnicas de Imagem Cardíaca/economia , Diagnóstico por Imagem/economia , Humanos , Espanha
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...